Liebert UPS, ENERGY STAR certified
Liebert GXT5LI-6000GVRT3UXLN
6,000 VA / 6,000 W double conversion UPS.
Capacity
6,000 VA
6,000 W real power
Topology
Double Conversion
Efficiency
94.5%
weighted, as tested
Runtime @ 50%
19 min
9 min at full load
A UPS has two ratings and the lower one is the limit. This unit is rated 6,000 VA and 6,000 W, so the equipment plugged into its battery outlets should draw no more than about 4,800 W if you want the usual 20% headroom. How to size a UPS.
Its weighted efficiency of 94.5% compares with a median of 94.6% across 98 certified units within 25% of its capacity.
- Maker
- Liebert
- Model
- GXT5LI-6000GVRT3UXLN
- Apparent power rating
- 6,000 VA
- Real power rating
- 6,000 W
- Power factor
- 1.00
- Topology
- Double Conversion
- Intended use
- Commercial, Data Center
- Battery
- Lithium-ion Battery
- Runtime at 50% load
- 19 min
- Runtime at 100% load
- 9 min
- Battery warranty
- 5 yr
- Weighted efficiency
- 94.5%
- Efficiency at 25 / 50 / 75 / 100% load
- - / 94.9% / 94.1% / 94.5%
- Rack mountable
- Yes, 3U
- Rated input voltage
- 200-240 V
- Rated output voltage
- 200-240 V
- Connections
- Ethernet,USB Port
- Size (H x W x D)
- 85 x 430 x 890 mm
- Maker take-back program
- No
- On the market since
- Mar 2024
- ENERGY STAR certified
- 8 Dec 2023
Source: ENERGY STAR certified uninterruptible power supplies dataset, US EPA, record 2839415, data build 2026-09-29. Figures are as the maker certified them. How we use this data.
Other makers
Machines comparable to the GXT5LI-6000GVRT3UXLN
Certified UPS units from other makers within 25% of its VA rating.
| Model | Capacity | Topology | Efficiency | Runtime @ 50% |
|---|---|---|---|---|
| Vertiv GXT5-6000IRT5UXLN | 6,000 VA / 6,000 W | Multi-Mode Double Conversion | 94.9% | 14 min |
| Vertiv GXE-06k00TL1102C00 | 6,000 VA / 5,400 W | Multi-Mode Double Conversion | 95.4% | 14 min |
| Eaton 9PX6Ki | 6,000 VA / 5,400 W | Double Conversion | 93.7% | 8 min |
| Eaton 9PX6K | 6,000 VA / 5,400 W | Double Conversion | 93.7% | 8 min |
| Vertiv GXT5-6000MVRT4UXLN | 6,000 VA / 6,000 W | Multi-Mode Double Conversion | 94.0% | 9 min |
| Vertiv GXT4-6000RT230 | 6,000 VA / 4,800 W | Multi-Mode Double Conversion | 93.8% | 17 min |
Liebert
More Liebert UPS battery backups
| Model | Capacity | Topology | Efficiency | Runtime @ 50% |
|---|---|---|---|---|
| 10B14763GG103 | 450 kVA / 405 kW | Multi-Mode Double Conversion | 97.2% | 30 min |
| 10B14789GF103 | 825 kVA / 743 kW | Multi-Mode Double Conversion | 97.7% | 30 min |
| 47SA040A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1] | 10 kVA / 10 kW | Multi-Mode Double Conversion | 94.2% | 34 min |
| 47SA100A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1] | 60 kVA / 60 kW | Multi-Mode Double Conversion | 95.8% | 10 min |
| 47SA120A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1] | 120 kVA / 120 kW | Multi-Mode Double Conversion | 95.6% | 10 min |
| 51SA030QAA | 30 kVA / 30 kW | Multi-Mode Double Conversion | 96.3% | 10 min |
| 51SA030QBA | 30 kVA / 30 kW | Multi-Mode Double Conversion | 95.2% | 10 min |
| 51SA050BAA | 50 kVA / 50 kW | Multi-Mode Double Conversion | 96.4% | 10 min |