Skip to content

CyberPower UPS, ENERGY STAR certified

CyberPower PR2000RTXL2U

2,000 VA / 2,000 W line interactive UPS.

Capacity

2,000 VA

2,000 W real power

Topology

Line Interactive

Efficiency

98.0%

weighted, as tested

Runtime @ 50%

13 min

4 min at full load

A UPS has two ratings and the lower one is the limit. This unit is rated 2,000 VA and 2,000 W, so the equipment plugged into its battery outlets should draw no more than about 1,600 W if you want the usual 20% headroom. How to size a UPS.

Its weighted efficiency of 98.0% compares with a median of 98.3% across 183 certified units within 25% of its capacity. With nothing plugged in it still draws 6.4 W, about $7.25 a year at 13¢/kWh just to stand ready.

Maker
CyberPower
Model
PR2000RTXL2U
Apparent power rating
2,000 VA
Real power rating
2,000 W
Power factor
1.00
Topology
Line Interactive
Intended use
Consumer
Battery
Valve Regulated Lead-acid Battery
Runtime at 50% load
13 min
Runtime at 100% load
4 min
Battery warranty
3 yr
Weighted efficiency
98.0%
Efficiency at 25 / 50 / 75 / 100% load
98.3% / 98.4% / 98.1% / 97.8%
Input power at no load
6.4 W
Rack mountable
Yes
Rated input voltage
100-125 V
Rated output voltage
100-125 V
Connections
Serial Port,Ethernet,USB Port
Size (H x W x D)
87 x 433 x 500 mm
Maker take-back program
Yes
On the market since
Jul 2018
ENERGY STAR certified
8 Jun 2018

Certified under the same record

The maker lists these as the same machine or a variant of it: PR2000RT2UCN, PR2000RT2UC, PR2000RT2U JP, PR2000RT2U, PR2000RTXL2UCN, PR2000RTXL2UC.

Source: ENERGY STAR certified uninterruptible power supplies dataset, US EPA, record 2321482, data build 2026-09-29. Figures are as the maker certified them. How we use this data.

Other makers

Machines comparable to the PR2000RTXL2U

Certified UPS units from other makers within 25% of its VA rating.

ModelCapacityTopologyEfficiencyRuntime @ 50%
Delta RT-2K2,000 VA / 1,800 WDouble Conversion92.2%12 min
Liebert GXT5-2000LVRT2UXL2,000 VA / 1,800 WMulti-Mode Double Conversion92.5%9 min
Vertiv GXT5-2000LVRT2UXL2,000 VA / 1,800 WMulti-Mode Double Conversion92.5%9 min
Eaton 9PX2000RT2,000 VA / 1,800 WDouble Conversion92.5%20 min
Liebert GXT5-2000IRT2UXL2,000 VA / 2,000 WMulti-Mode Double Conversion92.9%9 min
Vertiv GXT5-2000IRT2UXL2,000 VA / 2,000 WMulti-Mode Double Conversion92.9%9 min

CyberPower

More CyberPower UPS battery backups

ModelCapacityTopologyEfficiencyRuntime @ 50%
AVRG1000LCD1,000 VA / 530 WLine Interactive98.6%10 min
BL1250U21,200 VA / 800 WLine Interactive98.7%11 min
BL1450U1,200 VA / 800 WLine Interactive98.7%11 min
BRG1000AVRLCD1,000 VA / 600 WLine Interactive98.5%9 min
BRG1500AVRLCD1,500 VA / 900 WLine Interactive98.6%12 min
BRG1500AVRLCD21,500 VA / 900 WLine Interactive98.8%11 min
CP1000PFCLCD1,000 VA / 600 WLine Interactive98.8%9 min
CP1000PFCLCDa1,000 VA / 600 WLine Interactive99.3%8 min

All CyberPower UPS battery backups