Skip to content

UPS battery backupsENERGY STAR certified

Minuteman ED5KRT

5,000 VA / 4,500 W double conversion UPS.

Capacity

5,000 VA

4,500 W real power

Topology

Double Conversion

Efficiency

93.8%

weighted, as tested

Runtime @ 50%

11 min

3 min at full load

A UPS has two ratings and the lower one is the limit. This unit is rated 5,000 VA and 4,500 W, so the equipment plugged into its battery outlets should draw no more than about 3,600 W if you want the usual 20% headroom. How to size a UPS.

Its weighted efficiency of 93.8% compares with a median of 94.6% across 98 certified units within 25% of its capacity.

Maker
Minuteman
Model
ED5KRT
Apparent power rating
5,000 VA
Real power rating
4,500 W
Power factor
0.90
Topology
Double Conversion
Intended use
Consumer, Commercial, Data Center
Battery
Valve Regulated Lead-acid Battery
Runtime at 50% load
11 min
Runtime at 100% load
3 min
Battery warranty
3 yr
Weighted efficiency
93.8%
Efficiency at 25 / 50 / 75 / 100% load
90.6% / 93.5% / 93.9% / 94.0%
Outlets
5 (5 battery + surge, 0 surge only)
Rack mountable
Yes, 3U
Rated input voltage
208-240 V
Rated output voltage
208-240 V
Connections
Serial Port,USB Port
Size (H x W x D)
173 x 438 x 591 mm
Maker take-back program
No
On the market since
Mar 2024
ENERGY STAR certified
29 Feb 2024

Source: ENERGY STAR certified uninterruptible power supplies dataset, US EPA, record 3417798, data build 2026-09-29. Figures are as the maker certified them. How we use this data.

Other makers

Machines comparable to the ED5KRT

Certified UPS units from other makers within 25% of its VA rating.

ModelCapacityTopologyEfficiencyRuntime @ 50%
Tripp Lite AGPS72555,000 VA / 4,500 WDouble Conversion93.3%11 min
Eaton 9PX5K5,000 VA / 4,500 WDouble Conversion92.9%8 min
Liebert GXT4-5000RT2305,000 VA / 4,000 WMulti-Mode Double Conversion93.6%22 min
Vertiv GXT4-5000RT2305,000 VA / 4,000 WMulti-Mode Double Conversion93.6%22 min
Liebert GXT4-5000RT2085,000 VA / 4,000 WMulti-Mode Double Conversion92.2%17 min
Vertiv GXT4-5000RT2085,000 VA / 4,000 WMulti-Mode Double Conversion92.2%17 min

Minuteman

More Minuteman UPS battery backups

ModelCapacityTopologyEfficiencyRuntime @ 50%
EC1000RTXL2U1,000 VA / 900 WDouble Conversion90.9%10 min
EC1500RTXL2U1,500 VA / 1,350 WDouble Conversion91.1%10 min
EC2000RTXL2U2,000 VA / 1,800 WDouble Conversion91.7%10 min
EC3000RTXL2U3,000 VA / 2,700 WDouble Conversion91.9%10 min
ED10KRT10 kVA / 9,000 WDouble Conversion93.9%7 min
ED6KRT6,000 VA / 5,400 WDouble Conversion93.9%7 min
ED8KRT8,000 VA / 7,200 WDouble Conversion94.1%11 min
EN450G450 VA / 250 WPassive Standby97.9%10 min

All Minuteman UPS battery backups