Vertiv UPS, ENERGY STAR certified

Vertiv Liebert APM2 FR1 c3 Series

20 kVA / 20 kW multi-mode double conversion UPS, model number 56S(c3)(d2)C(f)(g)(h)(i)(j).

Capacity

20 kVA

20 kW real power

Topology

Multi-Mode Double Conversion

Efficiency

95.8%

weighted, as tested

Runtime @ 50%

40 min

20 min at full load

A UPS has two ratings and the lower one is the limit. This unit is rated 20 kVA and 20 kW, so the equipment plugged into its battery outlets should draw no more than about 16 kW if you want the usual 20% headroom. How to size a UPS.

Its weighted efficiency of 95.8% compares with a median of 95.5% across 45 certified units within 25% of its capacity. With nothing plugged in it still draws 183.7 W, about $209 a year at 13¢/kWh just to stand ready.

Maker
Vertiv
Model
Liebert APM2 FR1 c3 Series
Model number
56S(c3)(d2)C(f)(g)(h)(i)(j)
Apparent power rating
20 kVA
Real power rating
20 kW
Power factor
1.00
Topology
Multi-Mode Double Conversion
Intended use
Consumer, Commercial, Data Center
Battery
Valve Regulated Lead-acid Battery
Runtime at 50% load
40 min
Runtime at 100% load
20 min
Battery warranty
1 yr
Weighted efficiency
95.8%
Efficiency at 25 / 50 / 75 / 100% load
94.3% / 96.1% / 96.6% / 96.9%
Input power at no load
183.7 W
Rack mountable
No
Modular
Yes
Rated input voltage
480 V
Rated output voltage
480 V
Connections
USB Port
Size (H x W x D)
2000 x 600 x 1029 mm
Maker take-back program
No
On the market since
Oct 2024
ENERGY STAR certified
28 Nov 2024

Certified under the same record

The maker lists these as the same machine or a variant of it: 56S(c3)(d2)E(f)(g)(h)(i)(j), 56S(c3)(d2)F(f)(g)(h)(i)(j), 56S(c3)(d2)H(f)(g)(h)(i)(j), 56S(c3)(d2)J(f)(g)(h)(i)(j), 56S(c3)(d2)L(f)(g)(h)(i)(j), 56S(c3)(d2)M(f)(g)(h)(i)(j), 56S(c3)(d2)N(f)(g)(h)(i)(j).

Source: ENERGY STAR certified uninterruptible power supplies dataset, US EPA, record 3815213, data build 2026-09-29. Figures are as the maker certified them. How we use this data.

Other makers

Machines comparable to the Liebert APM2 FR1 c3 Series

Certified UPS units from other makers within 25% of its VA rating.

ModelCapacityTopologyEfficiencyRuntime @ 50%
Schneider Electric Galaxy VS 30kW 480V w/o Batteries, Start-up 5x820 kVA / 20 kWMulti-Mode Double Conversion95.9%-
Schneider Electric GVSUPS80KGS20 kVA / 20 kWMulti-Mode Double Conversion95.9%-
Schneider Electric Galaxy VS 40kW 480V w/o Batteries, Start-up 5x820 kVA / 20 kWMulti-Mode Double Conversion95.9%-
Schneider Electric Galaxy VS 20kW 480V w/o Batteries, Start-up 5x820 kVA / 20 kWMulti-Mode Double Conversion95.9%-
Schneider Electric Galaxy VS 50kW 480V w/o Batteries, Start-up 5x820 kVA / 20 kWMulti-Mode Double Conversion95.9%-
Schneider Electric Galaxy VS 100kW 480V w/o Batteries, Start-up 5x820 kVA / 20 kWMulti-Mode Double Conversion95.9%-

Vertiv

More Vertiv UPS battery backups

ModelCapacityTopologyEfficiencyRuntime @ 50%
10B14763GG103450 kVA / 405 kWMulti-Mode Double Conversion97.2%30 min
10B14789GF103825 kVA / 743 kWMulti-Mode Double Conversion97.7%30 min
47SA040A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1]10 kVA / 10 kWMulti-Mode Double Conversion94.2%34 min
47SA100A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1]60 kVA / 60 kWMulti-Mode Double Conversion95.8%10 min
47SA120A[0|1|2|3][C|Y][0|F|H|M|G|L][0|1]120 kVA / 120 kWMulti-Mode Double Conversion95.6%10 min
51SA030QAA30 kVA / 30 kWMulti-Mode Double Conversion96.3%10 min
51SA030QBA30 kVA / 30 kWMulti-Mode Double Conversion95.2%10 min
51SA050BAA50 kVA / 50 kWMulti-Mode Double Conversion96.4%10 min

All Vertiv UPS battery backups